PLANOCOLOR SLR

Silicone enhanced plaster in paste form

Organic decorative plasters in the form of high-performance silicone hydrophobic paste. They are available in white color while upon request, these can be delivered pre colored in the 260 UV resistant NOVAMIX FACADE color chart shades. Available granulometries: 1,0mm (SLR 100) and 1,5mm (SLR 150). In ETICS they are applied over the base coat produced by using NOVABOND PS FLEXNOVABOND PS FIBER or NOVABOND THERMO with NOVAMIX THERMONET incorporation. On non-absorbent surfaces, prime by using PLANO BOND or PLANO CONTACT. PLANOCOLOR SLR plasters are part of the External Thermal Insulation Composite System (ETICS), NOVATHERM SYSTEM.

Consumption: 1,3-2,4 kg/m²
Color: White and colours of NOVAMIX FACADE colour chart
Package: Buckets 25 kg
Pallet: 600 kg

Description

  • PLANOCOLOR SLR ready to use silicone acrylic plaster is used as the finishing coat of rendering works on:
    • expanded and extruded polystyrene boards
    • mineral fiber board glass wool and rock wool boards
    • concrete, cement mortars, mortars and masonry mortars
    • cement boards and gypsum boards
    • metals using a suitable primer
    • old paints with good adhesion
  • Form: paste
  • Granulometry:
    • 1.0 mm (PLANOCOLOR SLR 100)
    • 1.5 mm (PLANOCOLOR SLR 150)
    • Drying time: touch dry in 4 - 6 hours
  • Application temperature: from +5°C up to +35°C

Substrate preparation:

Cement based substrates must be dry, compact, without cracks, free of dust, salts, grease and any other materials that could reduce adhesion of PLANOCOLOR SLR to them. If the substrate shows poor resistance should be consolidated using the special primer NOVADUR W. Smooth surfaces and / or non-absorbent surfaces should be primed using either PLANO BOND or PLANO CONTACT.

Application:

Before use stir well the material with an electric mixer at low speed. Stirring should be done with slow circular motions to avoid creating bubbles in the mass of the material. The mixture is applied using a flat metal spatula or rendering machine. Finish the surface in the fresh layer, about 15 to 20 minutes, with a plastic spatula. If containers are used different production code, it recommends mixing together before use, in order not to cause discolorations.

Recommendations:

  • Only apply to a structurally stable and properly prepared substrate
  • Avoid application at high temperatures, strong wind, rain or frost
  • Do not cover existing expansion joints of the substrate
  • Do not add cement, gypsum, lime or other additives that might affect the properties of the mortar
  • Do not apply it to the substrate and ambient temperatures below +5°C and higher than +35°C
  • For color uniformity ensure that you apply material of the same batch per parts of the facade
  • In case of application from different production batches, mix 2 or more containers in a larger one, so that the final shade is the same and uniform throughout the application surface
  • The final shade may be affected by the substrate, curing conditions and granulometry
  • Protect from rain or frost the first 24 hours
  • Application to be performed by professional user

Cleaning:

Buckets, tools, coatings etc. can be cleaned with water as long as the mix is still fresh. Once dried cleaning can be done only by mechanical means.

Legal Notice:

The technical data and recommendations included or listed are the outcome of laboratory measurements combined with our current knowledge and expertise. All information and specifications should in any case be considered as indicative. The Company makes every effort to ensure the accuracy of the information provided herein. Product specifications are subject to change without notice and may differ from product images. Due to printing and application procedures, the colors displayed here should be considered as indicative. In particular, variations in materials, substrates and on-site application conditions are such that no warranty can be given or implied reference to the suitability of the materials for trading or use for a particular purpose and conditions of any given project. Anyone interested in using the product must ensure beforehand that the product is suitable for the intended use and in any case, the user is solely responsible for any outcomes associated with the use of product. Among other things, the Company is not responsible for any normal wear or tear from environmental or any other unsuitable conditions. We reserve the right to revise or change the data herein without prior notice. Restrictions and disclaimers apply to the extent permitted by applicable law. The Company has a Technical Support Department, which has exclusive responsibility for providing technical advice and solutions, addressing relevant issues. Requests to the Technical Support Department are addressed and answered, only in writing. For the latest and valid version of the Technical Data Sheet, the user of the material must refer to our website www.novamix.gr.